×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Study on the Light Output Non-uniformity of PbWO4 Crystal

Get Citation
SHAO Ming, XU Tong, LIU Ming-Chang, WANG Cong-Rong, RUAN Li-Juan, CHEN Hong-Fang, PAN Xiao-Hui and WANG Cong-Zhou. Study on the Light Output Non-uniformity of PbWO4 Crystal[J]. Chinese Physics C, 2001, 25(6): 555-560.
SHAO Ming, XU Tong, LIU Ming-Chang, WANG Cong-Rong, RUAN Li-Juan, CHEN Hong-Fang, PAN Xiao-Hui and WANG Cong-Zhou. Study on the Light Output Non-uniformity of PbWO4 Crystal[J]. Chinese Physics C, 2001, 25(6): 555-560. shu
Milestone
Received: 2000-06-26
Revised: 1900-01-01
Article Metric

Article Views(3926)
PDF Downloads(631)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Study on the Light Output Non-uniformity of PbWO4 Crystal

    Corresponding author: SHAO Ming,
  • SHAO Ming 1 \ XU Tong\ LIU Ming Chang\ WANG Cong Rong RUAN Li Juan\ CHEN Hong Fang Department of Modern Physics, University of Science and Technology of China, Hefei\ 230026, China PAN Xiao Hui\ WANG Cong Zhou College of Mechanical and Auto Engineering, Hefei University of Technology, Hefei\ 230009, China

Abstract: This paper presents the measurement on the light output non uniformity of full size PbWO4 crystal, which will be used in the electromagnetic calorimeter (ECAL) of CMS detector. It makes use of the 22Na radiactive source and the coincident method. With the help of convolution fitting method, it is possible to make fine measurement on the light output non uniformity of the crystal. The effect of depolishing one of the lateral faces of the crystal on the non-uniformity has been studied. The slope of the non uniformity curve decreases with the increasing of the roughness. When the roughness reaches Rz=(1.49±0.27)μm the non uniformity curve meets the requirement of CMS ECAL.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return