Design of a New DC-RF Injector Used in High Average Power FEL

Get Citation
HU Yan-Le, ZHAO Kui, CHEN Jia-Er, ZHANG Bao-Cheng, HAO Jian-Kui and WANG Li-Fang. Design of a New DC-RF Injector Used in High Average Power FEL[J]. Chinese Physics C, 2001, 25(8): 787-792.
HU Yan-Le, ZHAO Kui, CHEN Jia-Er, ZHANG Bao-Cheng, HAO Jian-Kui and WANG Li-Fang. Design of a New DC-RF Injector Used in High Average Power FEL[J]. Chinese Physics C, 2001, 25(8): 787-792. shu
Milestone
Received: 2000-08-07
Revised: 1900-01-01
Article Metric

Article Views(2968)
PDF Downloads(646)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Design of a New DC-RF Injector Used in High Average Power FEL

    Corresponding author: HU Yan-Le,
  • Institute of Heavy Ion Physics, Peking University, Beijing 100871, China

Abstract: Here we give the design proposal of a new DC-RF injector used in high average power FEL. The injector includes a Pierce gun and a 1+1/2 SC cavity. It will be able to provide high average beam current because it can work in CW mode. By changing the shape of the first 1/2 cell of SC cavity to enforce the focusing effect, we can decrease the distance between photocathode and SC cavity. Thus, the growth of emittance can be suppressed effectively. Through the simulation of particle dynamics with PARMELA, the shape of Pierce gun and the optimized synchronous phase of the SC cavity can be decided. The simulation results show that this kind of injector is feasible.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return