×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Experiment and Operation of BEPCⅡ Electron Gun System

Get Citation
LIU Bo, GU Meng-Ping, WANG Shu-Hong, CHI Yun-Long, YANG Xing-Wang, TIAN Shuang-Min, LIU Wei-Bin and YE Qiang. Experiment and Operation of BEPCⅡ Electron Gun System[J]. Chinese Physics C, 2006, 30(5): 466-469.
LIU Bo, GU Meng-Ping, WANG Shu-Hong, CHI Yun-Long, YANG Xing-Wang, TIAN Shuang-Min, LIU Wei-Bin and YE Qiang. Experiment and Operation of BEPCⅡ Electron Gun System[J]. Chinese Physics C, 2006, 30(5): 466-469. shu
Milestone
Received: 2005-10-11
Revised: 2005-12-22
Article Metric

Article Views(2985)
PDF Downloads(720)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Experiment and Operation of BEPCⅡ Electron Gun System

    Corresponding author: GU Meng-Ping,
  • Institute of High Energy Physics, CAS, Beijing 100049, China

Abstract: The new electron gun system for the BEPCⅡ was tested on the test bench in July, 2004, and has been put into operation since Nov. 2004. This article describes the experiment results and operation status of this new system. The design current of the gun is 10A for the pulse length of 1ns single bunch or two bunches with repetition rate of 50Hz. The gun is operated with a pulsed high voltage power supply which can provide up to 200kV high voltage. Some important correlation curves are obtained during the experiment. Two-bunch operation is available and some elementary tests have been performed. The measurement results including beam current and beam emittance show that the simulations performed during design stage are roughly consistent with the practice. The practical operation shows that the design and manufacture are basically successful.

    HTML

Reference (1)

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return