×
近期发现有不法分子冒充我刊与作者联系,借此进行欺诈等不法行为,请广大作者加以鉴别,如遇诈骗行为,请第一时间与我刊编辑部联系确认(《中国物理C》(英文)编辑部电话:010-88235947,010-88236950),并作报警处理。
本刊再次郑重声明:
(1)本刊官方网址为cpc.ihep.ac.cn和https://iopscience.iop.org/journal/1674-1137
(2)本刊采编系统作者中心是投稿的唯一路径,该系统为ScholarOne远程稿件采编系统,仅在本刊投稿网网址(https://mc03.manuscriptcentral.com/cpc)设有登录入口。本刊不接受其他方式的投稿,如打印稿投稿、E-mail信箱投稿等,若以此种方式接收投稿均为假冒。
(3)所有投稿均需经过严格的同行评议、编辑加工后方可发表,本刊不存在所谓的“编辑部内部征稿”。如果有人以“编辑部内部人员”名义帮助作者发稿,并收取发表费用,均为假冒。
                  
《中国物理C》(英文)编辑部
2024年10月30日

Comparison of thermal neutron detection efficiency of 6Li scintillation glass and 3He gas proportional tube

Get Citation
XU Ming, TANG Zhi-Cheng, CHEN Guo-Ming and TAO Jun-Quan. Comparison of thermal neutron detection efficiency of 6Li scintillation glass and 3He gas proportional tube[J]. Chinese Physics C, 2013, 37(10): 106001. doi: 10.1088/1674-1137/37/10/106001
XU Ming, TANG Zhi-Cheng, CHEN Guo-Ming and TAO Jun-Quan. Comparison of thermal neutron detection efficiency of 6Li scintillation glass and 3He gas proportional tube[J]. Chinese Physics C, 2013, 37(10): 106001.  doi: 10.1088/1674-1137/37/10/106001 shu
Milestone
Received: 2012-12-05
Revised: 2013-03-18
Article Metric

Article Views(2030)
PDF Downloads(240)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Comparison of thermal neutron detection efficiency of 6Li scintillation glass and 3He gas proportional tube

    Corresponding author: TANG Zhi-Cheng,

Abstract: We report on a comparison study of the 3He gas proportional tube and the 6Li incorporated scintillation glasses on thermal neutron detection efficiency. Both 3He and 6Li are used commonly for thermal neutron detection because of their high neutron capture absorption coefficient. By using a neutron source 252Cf and a paraffin moderator in an alignment system, we can get a small beam of thermal neutrons. A flash ADC is used to measure the thermal neutron spectrum of each detector, and the detected number of events is determined from the spectrum, then we can calculate the detection efficiency of different detectors. Meanwhile, the experiment has been modeled with GEANT4 to validate the results against the Monte Carlo simulation.

    HTML

目录

/

DownLoad:  Full-Size Img  PowerPoint
Return
Return