Thermal analysis and expected performance of the low energy instrument on board the HXMT satellite

Get Citation
WANG Yu-Sa, CHEN Yong, XU Yu-Peng, WANG Juan, CUI Wei-Wei, LI Wei, HAN Da-Wei, ZHANG Zi-Liang, CHEN Tian-Xiang, LI Cheng-Kui, YANG Yan-Ji, LIU Xiao-Yan, HUO Jia, ZHANG Jun-Min and ZHENG Yi-Qian. Thermal analysis and expected performance of the low energy instrument on board the HXMT satellite[J]. Chinese Physics C, 2010, 34(12): 1812-1817. doi: 10.1088/1674-1137/34/12/005
WANG Yu-Sa, CHEN Yong, XU Yu-Peng, WANG Juan, CUI Wei-Wei, LI Wei, HAN Da-Wei, ZHANG Zi-Liang, CHEN Tian-Xiang, LI Cheng-Kui, YANG Yan-Ji, LIU Xiao-Yan, HUO Jia, ZHANG Jun-Min and ZHENG Yi-Qian. Thermal analysis and expected performance of the low energy instrument on board the HXMT satellite[J]. Chinese Physics C, 2010, 34(12): 1812-1817.  doi: 10.1088/1674-1137/34/12/005 shu
Milestone
Received: 2010-02-01
Revised: 2010-04-06
Article Metric

Article Views(2814)
PDF Downloads(542)
Cited by(0)
Policy on re-use
To reuse of subscription content published by CPC, the users need to request permission from CPC, unless the content was published under an Open Access license which automatically permits that type of reuse.
通讯作者: 陈斌, [email protected]
  • 1. 

    沈阳化工大学材料科学与工程学院 沈阳 110142

  1. 本站搜索
  2. 百度学术搜索
  3. 万方数据库搜索
  4. CNKI搜索

Email This Article

Title:
Email:

Thermal analysis and expected performance of the low energy instrument on board the HXMT satellite

    Corresponding author: WANG Yu-Sa,

Abstract: The Low Energy X-ray Instrument (LE) of the Hard X-ray Modulation Telescope (HXMT) uses the Swept Charge Device (SCD) to detect the X-rays in 1—15 keV. The performance of SCD is vulnerable to temperature. We analyzed the thermal condition of LE at different satellite working attitudes with the Finite Element Method (FEM). It is shown that the angle between the sunlight and the normal line of the barrier should be less than 26°, to keep the SCD detectors working in the required temperature range, i.e. -40 ℃ to -80 ℃. We find that the performance of LE is very stable in this temperature range, with a typical energy resolution of 160 eV at 5.9 keV.

    HTML